Accident Summary Nr: 200532240 - Operator Is Killed When Crane Tips Over

Accident Summary Nr: 200532240 -- Report ID: 0751910 -- Event Date: 05/20/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31230761405/20/20081622237310A.M. Cohron & Son, Inc.

Abstract: On May 20, 2008, Employee #1 was operating an American Crane (Model Number 4250) to remove a 30 ft bridge I-beam. When the crane tipped over, he was killed. Employee #1 was not aware that the crane was overloaded because the superintendent underestimated its weight.

Keywords: BEAM, DEMOLITION, OVERLOADED, SUSPENDED LOAD, BRIDGE, CRANE OPERATOR, CRANE, OVERTURN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge Demolition $20,000,000 and over 150 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312307614 Fatality Other Crane and tower operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.