Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200532059 - Employee Is Killed When Crushed by Hydraulic Lift

Accident Summary Nr: 200532059 -- Report ID: 0751910 -- Event Date: 02/10/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31184771902/12/20081541236210Fagen, Inc.

Abstract: At approximately 9:30 a.m. on February10, 2008, Employee #1, an electrician's helper, was operating a self-propelled hydraulic lift to visually inspect electrical connections. The operator's platform was rotated 180 degrees from the primary station. Employee #1 moved the lift forward, which could be driven from the platform, while the boom was extended 14 feet in the air. Employee #1 was facing in the opposite direction of the movement of the lift, and in this position, the platform controls moved the lift in the opposite direction of the machine motion. Employee #1 was struck and caught between an I-beam and the top rail of the platform at neck level. He was found in this position by two coworkers. One of the coworkers accessed the platform, but was unable to move the equipment due to the position of Employee #1. The other coworker found a key to override the platform controls and lowered the platform. Employee #1 was given CPR, but was pronounced dead at the site by the county examiner.

Keywords: BEAM, HYDRAULIC LIFT, ELECTRICIAN, CONSTRUCTION, CAUGHT BETWEEN, CRUSHED, WORK PLATFORM, UNSTABLE POSITION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery New project or new addition $5,000,000 to $20,000,000 2 40 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311847719 Fatality Asphyxia Electricians' apprentices Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior plumbing, ducting, electrical work
Fatality Cause: Lifting operations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close