Accident Summary Nr: 200531648 - Employee Is Injured in Trench Cave-In

Accident Summary Nr: 200531648 -- Report ID: 0751910 -- Event Date: 05/21/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31008676405/23/20071794238910Kruser Excavating

Abstract: At approximately 9:00 a.m. on May 21, 2007, Employee #1, a laborer, and a coworker were trenching a sewer and water line into a residential building lot. The trench was approx 8.5 ft deep and 38 ft long. The width at the bottom of the trench was approximately 3 ft. The trench walls were sloped out at the top, the southern portion approximately 8 ft and the northern portion approximately 5 ft. The soil was a clay-sand mixture and water was seeping from the west trench wall. The coworker was operating an excavator and conducted only a visual analysis of the soil. Employee #1 was in the trench installing pipe. As Employee #1 was unrolling the water line in the trench, the west trench wall collapsed, striking and burying him up to his waist. Employee #1 was able to extricate himself. He was hospitalized with a broken clavicle, bruised pancreas, and an approximately 3-in. tear in his liver.

Keywords: FRACTURE, SAND, SHOULDER, COLLAPSE, TRENCH, INDUSTRIAL TRUCK, STRUCK BY, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $50,000 to $250,000 1

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310086764 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.