Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200531614 - Employee's Fingers Amputated When Caught in Bandsaw

Accident Summary Nr: 200531614 -- Report ID: 0751910 -- Event Date: 04/13/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31008645905/08/20073365331524Nelson Company

Abstract: On April 13, 2007, Employee #1 was cutting a 2-inch by 2-inch piece of stock on a Well #1200 bandsaw. He was attempting to put coolant into the coolant tank, with the saw still running, but metal shavings were preventing the coolant from going into the tank. He attempted to remove the shavings with his hand and the blade caught his glove, pulling his hand up into the unused portion of the blade and amputating his finger(s).

Keywords: AMPUTATED, BANDSAW, FINGER, GLOVE, MACHINIST, WORK RULES, CAUGHT BY, LOCKOUT, FOUNDRY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310086459 Non Hospitalized injury Amputation Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.