Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200520773 - Employee's finger amputated by fan belt

Accident Summary Nr: 200520773 -- Report ID: 0751910 -- Event Date: 06/24/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
11509027608/31/199850830Martin Equipment Of Ia-Il, Inc.

Abstract: Employee #1's finger became caught in a fan belt and was amputated.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, ROTATING KNIFE, WORK RULES, CAUGHT BY, LOCKOUT, FAN BELT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115090276 Hospitalized injury Amputation Farm equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close