Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200515377 - Employee Is Killed in Trench Cave-In

Accident Summary Nr: 200515377 -- Report ID: 0552700 -- Event Date: 07/12/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31568037107/13/20111794238910Rmg Construction Contractors Llc
Inspection NrDate OpenedSICNAICSEstablishment Name
31568034807/13/20111794238910Metro Building Systems Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
31568035507/13/20111794238910Superior Excavating
Inspection NrDate OpenedSICNAICSEstablishment Name
31568036307/13/20111794238910Sub-It Contractors Inc

Abstract: At approximately 9:15 a.m. on July 13, 2011, Employee #1, of RMG Construction Contractors Llc, was performing excavation work at a Public Storage building in Brooklyn Park, MN to fix a lower level water leak. A trench was dug by Superior Excavating, a sub-contractor, with a mini-back hoe to approximately 6 ft deep. Employee #1 and another subcontract employee were taking turns hand digging around the water pipe, trying to reach the bottom of the foundation. The excavated wall of the trench collapsed on Employee #1. The owner of RMG witnessed the cave-in and stated it threw Employee #1 up against the block foundation wall and dirt covered him to around mid-stomach to shoulder level. Employee #1 was not coherent, eventually lost consciousness, and died before he could be removed from the trench.

Keywords: EXCAVATION, UNCONSCIOUSNESS, SHOULDER, COLLAPSE, TRENCH, CAVE-IN, BACKHOE, STOMACH
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Maintenance or repair Under $50,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 315680371 Fatality Other Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Wall (earthen) collapse
2 315680348 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
3 315680355 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
4 315680363 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.