Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200514297 - Employee Is Killed in Fall from Tower Crane

Accident Summary Nr: 200514297 -- Report ID: 0552700 -- Event Date: 11/06/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
31063221111/07/20061791238190Sowles Co.

Abstract: On November 6, 2006, Employee #1 was on a tower crane near the 39th floor. He was installing a second transfer rail to dismantle the crane. Employee #1 was observed walking and/or crouching on a 9.5-in.-wide steel beam of the jacking cage without adequate fall protection. The witness saw Employee #1's left ankle roll to the left, causing him to lose his balance and near the mid-rail of the catwalk. When the mid-rail failed, Employee #1 fell approximately 340 ft to a patio at the 5th floor level. He was killed.

Keywords: BEAM, FRACTURE, DISMANTLING, TOWER CRANE, CONSTRUCTION, FALL, FALL PROTECTION, LOST BALANCE, WORK SURFACE, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition $20,000,000 and over 41 410 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310632211 Fatality Fracture Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: 410 feet
Cause: Steel Erection Of Solid Web-Moving Point To Point
Fatality Cause: Fall from/with platform catwalk (attached to struc

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.