Accident Summary Nr: 200513430 - Employee Killed in Fall from Carpenters' Bracket Scaffold

Accident Summary Nr: 200513430 -- Report ID: 0552700 -- Event Date: 01/21/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30713290201/22/20041761238160Witucki Construction

Abstract: On January 20, 2004, Employee #1, an employee of Witucki Construction, was roofing while standing on a carpenters' bracket scaffold when one of the brackets failed and he fell approximately 15 feet and struck his head, sustaining a severe closed head injury brain injury. Employee #1 was removed from life support two days after the accident. The bracket failed because it was installed with nails and not screws or lag bolts.

Keywords: HEAD, NAIL, ROOF, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, FALL, FALL PROTECTION, BRAIN, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $50,000 to $250,000 1 12 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307132902 Fatality Other Roofers Distance of Fall: feet
Worker Height Above Ground/Floor: 15 feet
Cause: Roofing
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.