Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200460780 - Employee bleeds to death when struck by piece of wood

Accident Summary Nr: 200460780 -- Report ID: 0111400 -- Event Date: 09/18/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
11629835709/18/20002434337110Homeland Builders, Incorporated

Abstract: Employee #1 was walking behind a table saw operator who was cutting 1/8 in. thick shims from an 82 in. long piece of maple. The blade was at a slight angle on the saw and the shims were being cut against the table fence. The operator had just finished a cut and was reaching over to retrieve the shim from between the saw blade and the fence when it became jammed and a small sharp piece of wood kicked back and penetrated Employee #1's chest. He removed the piece of wood himself and was transported to the hospital, where he was pronounced dead at 8:25 a.m. from excessive loss of blood. The employer had purchased the table saw in June 2000. He removed the original guard that came with the saw, which consisted of a spreader, anti-kickback fingers, and a blade guard. The employer had put on a Biesemeyer T-square blade guard, but had never reinstalled the spreader or anti-kickback fingers.

Keywords: CHEST, KICK BACK, IMPALED, GUARD, STRUCK BY, FLYING OBJECT, UNGUARDED, PUNCTURE, TABLE SAW

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116298357 Fatality Puncture Cabinet makers and bench carpenters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close