Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200460640 - Three employees injured by exposure to cyanide

Accident Summary Nr: 200460640 -- Report ID: 0111400 -- Event Date: 01/24/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30291904801/27/200034990E.A. Dion, Incorporated

Abstract: Employees #1 through #3 worked on buffing and punch press machines at the E.A. Dion Corporation. They suffered from exposure to cyanide and were hospitalized. An inspection was conducted upon notification by the Public Health Department. It revealed a lack of hazard communication training, insufficient exposure assessment for cyanide or hydrogen peroxide, insufficient labeling, inadequate PPE, improper selection of respiratory protection equipment, inadequate work practices and engineering controls for mixing hydrogen peroxide and sodium cyanide, and several safety violations.

Keywords: PPE, WORK RULES, INHALATION, CHEMICAL VAPOR, POISONING, PRESS OPERATOR, PUNCH PRESS, UNTRAINED, CYANIDE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302919048 Hospitalized injury Poisoning(Systemic) Punching and stamping press machine operators
2 302919048 Hospitalized injury Poisoning(Systemic) Punching and stamping press machine operators
3 302919048 Hospitalized injury Poisoning(Systemic) Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.