Accident Summary Nr: 200460202 - Employee killed when struck by wooden pile

Accident Summary Nr: 200460202 -- Report ID: 0111400 -- Event Date: 03/11/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30205588403/11/199816290Allied Pile Driving, Incorporated

Abstract: Employee #1, a pile driver, was in a 15 ft deep pit where he was spotting 50 ft long wooden piles. The hammer came down and struck a pile that was about 12 in. off the ground, knocking the pile into Employee #1, pinning him against a trench box. He sustained crushing head injuries and was killed.

Keywords: HEAD, PILE DRIVER, PINNED, CONSTRUCTION, CAUGHT BETWEEN, CRUSHED, PIT, STRUCK BY
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge New project or new addition $20,000,000 and over 15 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302055884 Fatality Bruise/Contus/Abras Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pile driving
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.