Accident Summary Nr: 200451862 - Three Employees Are Overexposed to Toxic Chemical

Accident Summary Nr: 200451862 -- Report ID: 0418600 -- Event Date: 05/13/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30878952805/13/20052879325320Amvac Chemical Company

Abstract: On April 18, 2005, Employees #1, #2, and #3 were working on a new repackaging line for the pesticide BIDRIN (dicrotophos), which is an organophosphate pesticide. It has an LD-50 of 22 mg/kg, which places it in the highly toxic category, and is rapidly absorbed through the skin. The line operation consisted of equipment that automatically filled one gallon containers of BIDRIN. During the first four weeks of operation, the line had multiple problems including overfilling of bottles, failure of hoses and filling nozzles, tipping over of bottles on the line, puncture of bottles by conveyor equipment, and incomplete installation of caps and seals. These problems led to spillage of the material that required clean-up. Employees #1, #2, and #3 were cleaning up spillage when they were overexposed to the material. All three employees were hospitalized for treatment. According to the employee's accounts, the material contacted their clothing and skin during the clean-up operations. Review of the employee's PPE showed that the employees wore safety glasses, NOMEX coveralls, safety boots with butyl rubber soles that extended 3 to 4 inches up the side of the boot, and nitrile gloves that varied in thickness between 4 mil, 5 mil, and 13 mil. Employees reported that the 4 mil gloves would degrade and tear easily. Dicrotophos does not have an OSHA PEL but does have an ACGIH Biological Exposure Index for Cholinesterase inhibition (depression).

Keywords: CLEANING, INHALATION, SKIN, SPILL, TOXIC FUMES, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308789528 Hospitalized injury Poisoning(Systemic) Packaging and filling machine operators
2 308789528 Hospitalized injury Poisoning(Systemic) Packaging and filling machine operators
3 308789528 Hospitalized injury Poisoning(Systemic) Packaging and filling machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.