Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200451219 - Employee killed when struck by hydraulic arm

Accident Summary Nr: 200451219 -- Report ID: 0418600 -- Event Date: 03/22/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30483890703/22/200215410Tes Contracting Co., Inc.

Abstract: On March 22, 2002, Employee #1 was working alone in a cooling bed pit in the finishing department of a steel mill. He was struck by one of the cooling bed hydraulic arms, causing blunt force injuries of his head and chest, and killing him.

Keywords: CHEST, HEAD, STEEL, HYDRAULIC TOOL, STRUCK BY
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304838907 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior plumbing, ducting, electrical work
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.