Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200410611 - One employee killed, eight injured in storage tank explosion

Accident Summary Nr: 200410611 -- Report ID: 0317300 -- Event Date: 07/17/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30031186708/13/200142120J R Trucking Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
30031188308/13/200135670Shared System Technology
Inspection NrDate OpenedSICNAICSEstablishment Name
30031182607/17/20012911324110Motiva Enterprises Llc
Inspection NrDate OpenedSICNAICSEstablishment Name
30031185907/18/200149110Conectiv Operating Services Company
Inspection NrDate OpenedSICNAICSEstablishment Name
30031182607/17/20012911324110Motiva Enterprises Llc

Abstract: Motiva Enterprises LLC, is a refinery. Motiva has a subcontractor, Washington Group International Inc., which is responsible for the majority of the maintenance activities at the refinery. At 2:00 p.m. on July 17, 2001, four employees of Washington Group were directed to remove a section of grating for a catwalk around an acid storage tank in the acid tank farm. The tank farm consists of six atmospheric storage tanks. Each one is 47-feet high by 32-feet wide. The tanks contain spent and fresh sulfuric acid. The employees were replacing grating around one of the tanks in the morning, which was conducted without incident. After lunch, the employees proceeded to another area of the tank farm and began to remove the grating around Tank 393. Tank 393 had various holes in the tank. The tank contained spent sulfuric acid from the alkylation process in the refinery. The spent sulfuric acid contains approximately five to eight hydrocarbons with a flash point below 100 degrees Fahrenheit. The employees were removing the grating with an air arc. During the course of removing the grating there was an explosion. Employee #1 was killed and eight other employees were injured and hospitalized.

Keywords: GRATING, STORAGE TANK, EXPLOSION, REFINERY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300311867 Hospitalized injury Other Truck drivers, heavy
2 300311883 Hospitalized injury Asphyxia Laborers, except construction
3 300311826 Hospitalized injury Other Welders and cutters
4 300311826 Hospitalized injury Other Welders and cutters
5 300311826 Fatality Other Welders and cutters
6 300311859 Hospitalized injury Other Power plant operators
7 300311859 Hospitalized injury Other Laborers, except construction
8 300311826 Hospitalized injury Other Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.