Accident Summary Nr: 200375830 - Employee Gets Caught in or Between and Gets Scalped

Accident Summary Nr: 200375830 -- Report ID: 0454510 -- Event Date: 01/30/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31620023702/01/20122679322299Morcon Inc

Abstract: At approximately 8:30 a.m. on January 30, 2012 Employee #1 of Morcon Inc., went behind the paper napkin making machine that Employee #1 was operating. The two yellow mesh gate (guards) doors at the back of the napkin machine were open. Employee #1 found paper on the floor and squatted down to get the paper off the floor, when her hair in a pony tail, came in contact with a rotating horizontal shaft of the running napkin machine, resulting in scalping of Employee #1. The guard gate doors were opened by operator while machine was running. No interlock or locks were provided on the machine to shut off the machine when guard doors were opened. Operators performed servicing and maintenance (cleaning, lubricating, unjamming) of equipment without having training as authorized employees and without being provided with lockout capability.

Keywords: SCALP, LOCKOUT, CAUGHT BETWEEN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316200237 Hospitalized injury Other Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close