Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200375798 - Employee Is Fatally Caught in an Excavation Collapse

Accident Summary Nr: 200375798 -- Report ID: 0454510 -- Event Date: 12/19/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31619841512/19/20111795238910Dh Griffin Wrecking Co

Abstract: On December 19, 2011 Employee #1, an excavator operator, of DH Griffin Company exited his cab and entered the excavation he was digging. The excavation site was a large swimming pool shaped open pit measuring approximately 34 feet by 75 feet and up to 13 feet at its deeper end. A wall of spoils pile dirt lined the southeastern wall of the excavation with a service road just wide enough for a skid steer to operate up and down the side of it. The north/western side was fairly open with the exception of one spoils pile of dirt left on a concrete pad at the excavation edge. Within 20 yards of this area, Employee #1 was operating to remove soil from the pit and loading it into the dump trailers that had backed up to this same area. Speculation was that Employee #1 entered the excavation to examine an area where a foul fuel-like odor emanated from a recently removed bucket of soil. Within seconds of entering the excavation, the side wall exploded outward striking Employee #1 from behind and burying him completely. Witnesses to the event quickly ran to his aid in an effort to free him from the soil. Emergency services arrived to complete the rescue efforts and transported him to the hospital. Employee # 1 was later pronounced dead. He had sustained fatal injuries from the weight of the soil as it struck him to body and head.

Keywords: EXCAVATION, HEAD, COLLAPSE, FALL, BURIED, CONCRETE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Alteration or rehabilitation Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 316198415 Fatality Asphyxia Excavating and loading machine operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Wall (earthen) collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.