Abstract: On March 19, 2010, Employee #1, an employee of Southern Specialty Services, was taking measurements in a permit required confined space. While exiting, Employee #1 was exposed to an oxygen deficient atmosphere and fell from a ladder into the bottom of the vessel.

Keywords: ENCLOSED SPACE, OXYGEN DEFICIENCY, UNCONSCIOUSNESS, INHALATION, SHIP
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Maintenance or repair $50,000 to $250,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314083064 Hospitalized injury Asphyxia Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.