Accident Summary Nr: 200374445 - Employee asphyxiated when ground near trench collapses

Accident Summary Nr: 200374445 -- Report ID: 0454510 -- Event Date: 11/08/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31150534111/08/20071623237110Tugaloo Pipeline, Inc

Abstract: On November 8, 2007, Employee #1 was standing on the side of a trench, checking it and the surrounding area for tools and similar items left at the end of the work day. He was standing near the roadway, between the traffic barricades and the trench, when the ground caved in underneath him. Employee #1 was buried under between 8 ft and 15 ft of soil. He died of asphyxia. The trench box was in place at the time of the accident.

Keywords: EXCAVATION, ASPHYXIATED, CONSTRUCTION, TRENCH, UNSTABLE SOIL, BURIED, CAVE-IN, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $1,000,000 to $5,000,000 24 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311505341 Fatality Other Supervisors; plumbers, pipefitters & steamfitters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.