Accident Summary Nr: 200371508 - Electric Shock - Contact with Overhead Line thru Boom

Accident Summary Nr: 200371508 -- Report ID: 0454510 -- Event Date: 04/16/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30354884604/18/200116290Associated Industrial Construction, Inc.

Abstract: Employees were working on a project to expand a water treatment facility. They were using a crane to lift buckets of gravel into a trench to build up the bed for a concrete pour. The crane contacted a 23-kilovolt overhead power line. An employee on the ground who was touching the crane bucket was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E C, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant New project or new addition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303548846 Fatality Electric Shock Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.