Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200370393 - Two employees exposed to chlorine gas

Accident Summary Nr: 200370393 -- Report ID: 0454510 -- Event Date: 02/01/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30241855303/10/199942130Howard Lisk Trucking Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
30241848802/23/199922610West Point Stevens, Inc.

Abstract: Employees #1 and #2 worked at the wastewater treatment facility of a textile finishing plant. They were helping a tanker truck driver unload a shipment of sodium hypochlorite that had been misidentified as ferric chloride by plant security personnel. The security person relayed the mistaken product identity to the wastewater plan manager who passed on the information verbally Employees #1 and #2. They told the truck driver to connect the truck delivery hose to the ferric chloride tank and to begin pumping. As the sodium hypochlorite entered the storage tank, the chemical reaction of the mixture began to release chlorine gas into the atmosphere. Employees #1 and #2 were nearly overcome, but they managed to run away from the vapors.

Keywords: DELIVERY WORK, INHALATION, CHLORINE, AIR CONTAMINATION, OFF LOADING, CAUSTIC, SODIUM HYPOCHLORITE, CHEMICAL REACTION, RESPIRATORY TRACT, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302418553 Hospitalized injury Other Truck drivers, heavy
2 302418488 Hospitalized injury Other Water and sewage treatment plant operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.