Accident Summary Nr: 200356038 - Worker Clearing Jam in Confined Space Is Asphyxiated

Accident Summary Nr: 200356038 -- Report ID: 0453710 -- Event Date: 03/06/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31050549003/06/20073273327320S & W Ready Mix Concrete Company

Abstract: On March 6, 2007, Employee #1 was working as a batch operator for a manufacturer of ready-mixed concrete. While attempting to clear a jam, he entered a confined space without using confined space entry procedures, observing lockout/tagout protocol, or removing the power to the equipment. The confined space was in a metal structure that contained sand and gravel aggregate in elevated bins approximately 35 feet above grade. The bins were programmed to dispense predetermined quantities of aggregate into a lower hopper. The lower hopper was an aggregate weight scale, and the different kinds of aggregate were combined there. The aggregate weight scale was a tapered metal bin that funneled the aggregate onto a conveyor through bottom-mounted pneumatically-actuated doors. The material went onto a conveyor that lifted the material and dropped it into truck-mounted mixers. When the jam was cleared, Employee #1 was still inside the bin. At that moment, the overhead gravity-fed aggregate bins automatically released a predetermined load of sand and gravel, engulfing and killing him. Death was due to asphyxiation.

Keywords: ASPHYXIATED, SAND, CONFINED SPACE, CAUGHT BY, LOCKOUT, MECH MAT HANDLING, FALLING OBJECT, CONCRETE, HOPPER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310505490 Fatality Asphyxia Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close