Accident Summary Nr: 200354538 - Employee injured when excavator arm contacts power line

Accident Summary Nr: 200354538 -- Report ID: 0453710 -- Event Date: 04/27/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30877995805/09/20051711238910Rea Contracting Llc

Abstract: On April 27, 2005, Employee #1 was operating a Caterpillar 318 excavator when the knuckle of the boom contacted a 13,600 volt overhead power line. Afterward, Employee #1 stated that his left arm felt numb and hot. He was transported to the UNC Chapel Hill burn unit, where he was hospitalized overnight and released the following day.

Keywords: BURN, CLEARANCE, OVERHEAD POWER LINE, WORK RULES, EQUIPMENT OPERATOR, STRUCK AGAINST, CONSTRUCTION, ELECTRIC SHOCK, EXCAVATOR, ARM
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Maintenance or repair $1,000,000 to $5,000,000 18

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 308779958 Hospitalized injury Electric Shock Miscellaneous material moving equipment operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.