Accident Summary Nr: 200340974 - Employee Caught Between Platform and Conveyor, Asphyxiated

Accident Summary Nr: 200340974 -- Report ID: 0523900 -- Event Date: 12/01/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31317917812/01/20104491488320Burlington Northern Santa Fe (Bnsf)

Abstract: At approximately 6:15 a.m. on December 1, 2010, Employee #1 was assisting a coworker with the thawing of arc gates, which would allow frozen taconite pellets to feed onto a shuttle conveyor system at Station Number 24. The conveyor system was loading the pellets into a cargo ship at a material handling terminal. When taconite facility employees thaw the arc gates, they put a shuttle control switch into the "local" position so a ship loader would be unable to control movement of the conveyor shuttle from the remote ship loader's station. Employee #1 stepped up onto the shuttle conveyor framework to get closer to an arc gate with a hand-held propane torch. However, before he stepped onto the shuttle structure, he accidentally switched the shuttle conveyor control into the "remote" position, but was unaware of it, since the indicator light was burnt out. This gave another coworker, the ship loader, control of the shuttle conveyor movement. While Employee #1 was standing on the shuttle structure, the ship loader moved all 16 shuttle conveyors approximately 3 ft in a reverse direction. This movement of the shuttle conveyor caught and trapped Employee #1 in an approximate 7 in. wide space between the shuttle structure and a small fixed elevated working platform, where a coworker was standing and also thawing the arc gate with a separate propane torch. The coworker attempted to help Employee #1, but the forces of the conveyor system and the platform on his body asphyxiated him. The factors that contributed to the event included a failure to lock out the conveyor shuttle, an unguarded moving conveyor adjacent to the danger zone, powered conveyors started before employees were cleared of the conveyor and an inoperable safety device.

Keywords: ASPHYXIATED, CAUGHT BY, LOCKOUT, CAUGHT BETWEEN, CONVEYOR, SHIP, CONTAINERIZED CARGO, ELEVATED WORK PLAT, UNGUARDED, MACHINE--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 313179178 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close