Accident Summary Nr: 200340586 - Employee Receives Multiple Injuries in Trench Cave-In

Accident Summary Nr: 200340586 -- Report ID: 0523900 -- Event Date: 08/01/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30703986708/02/20051794238910Peterson Lawn & Garden Services, Llc Dba Del'S Exc

Abstract: At approximately 2:45 p.m. on August 1, 2005, Employee #1 was performing a live tap on a water main with two coworkers in a trench. The trench was excavated to a depth of approximately 80-in. at the point where the water main was located. The overall trench depth ranged from approximately 74-in. to 82-in., with a total trench length of approximately 51.5 ft. The trench walls were excavated vertically, with no indication of sloping or benching. The width of the trench ranged from approximately 46-in. at the North end and up to a maximum of approximately 58-in. at the south end. A competent person was not on site, and workers had not received any specific training on excavation requirements such as utilization of protective systems, soil classification, and recognition of cave-in hazards. The trench collapsed and one coworker was uninjured, and one coworker received minor injuries that were not recorded. Employee #1 was completely buried and sustained crushing injuries to his pelvis, hips, and ankle. Employee #1 was hospitalized.

Keywords: EXCAVATION, COLLAPSE, UNSECURED, TRENCH, PELVIS, SHORING, BURIED, UNTRAINED, HIP, ANKLE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Excavation, landfill Other Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307039867 Hospitalized injury Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Wall (earthen) collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.