Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200331676 - Employee Is Killed When Struck in Head by Machine Part

Accident Summary Nr: 200331676 -- Report ID: 0830300 -- Event Date: 12/21/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30952590512/23/20053523333111Farm Aid Manufacturing Company

Abstract: On December 21, 2005, Employee #1 was operating an engine lathe. Employee #1 used a piece of flat iron to rotate the chuck in order to access the key slot. The piece of flat iron was left in the chuck. The lathe was turned on, and the piece of flat iron snagged the chuck guard and ripped the guard from the machine and struck Employee #1 in the head, killing him.

Keywords: HEAD, LATHE, GUARD, MACHINE OPERATOR, IRON, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309525905 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.