Accident Summary Nr: 200270148 - Employee killed when struck by falling lift
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300215100 | 12/04/1996 | 3081 | 0 | Tenneco Packaging |
Abstract: Employee #1 was running a new wire to a material lift table. The table had been raised using a forklift and was blocked to prevent it from falling. Once he had finished wiring the hydraulic motor, he removed the supporting blocks. The lift fell, striking Employee #1 on the head. He was killed. The lift dropped because there was no hydraulic fluid in the back cylinder.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300215100 | Fatality | Fracture | Occupation not reported |