Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200270056 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Accident Summary Nr: 200270056 -- Report ID: 0524500 -- Event Date: 05/13/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12219661105/14/199617110All Tri-R, Inc.

Abstract: An employee was helping a crane operator move a precast concrete slab. The crane contacted a 34.5-kilovolt overhead power line while the employee was touching the concrete slab. The employee received an electric shock and was transported to a hospital, where he was pronounced dead. He had been electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122196611 Fatality Electric Shock Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close