Accident Summary Nr: 200264307 - Employee Is Killed When Caught in Machine

Accident Summary Nr: 200264307 -- Report ID: 0627100 -- Event Date: 09/06/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31584806909/07/20113312331221Cmc Steel Arkansas

Abstract: On September 6, 2011, Employee #1 was removing the lifting cable from an overhead crane hoist. When he signaled to jog the drum to position it for the cable removal, his safety lanyard became tangled in a rotating shaft that drove the hoist drum's gear box. Employee #1 was pulled backwards, his head struck against the hoist structure, and he was killed.

Keywords: HEAD, WIRE ROPE, SAFETY BELT, STRUCK AGAINST, CAUGHT BY, HOIST, LANYARD, ENTANGLED, CRANE, HOISTLINE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315848069 Fatality Fracture Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.