Accident Summary Nr: 200261683 - Three employees killed in fall from communication tower

Accident Summary Nr: 200261683 -- Report ID: 0627100 -- Event Date: 01/02/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30482319801/03/200216230All States Construction, Inc.

Abstract: At approximately 3:40 p.m. on January 2, 2002, Employees #1, #2, and #3 were being hoisted up an approximately 400-foot Alltel telecommunication tower by a 0.875-inch, 3-strand manila rope to replace a guy at the 390-foot level and to reinforce the tower by adding 0.375-inch by 3-inch bar plates to the tower legs. When the employees reached approximately the 100-foot level, the rope broke and the employees fell to the ground. Employees #1, #2, and #3 were killed.

Keywords: MAINTENANCE, HOIST, GUY, FALL, TOWER, HOISTLINE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Alteration or rehabilitation Under $50,000 400 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304823198 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 100 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall, other
2 304823198 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 100 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall, other
3 304823198 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 100 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.