Accident Summary Nr: 200230183 - Employee's hand amputated in power press

Accident Summary Nr: 200230183 -- Report ID: 1032500 -- Event Date: 04/10/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30020405404/16/199737140Carlisle Spring Brake Products, Inc.

Abstract: Employee #1 was operating a part-revolution, mechanical power press when its timing chain broke. The press continued to cycle, partially amputating Employee #1's right hand. The second chain was missing from the press; had it been present, it would have provided some control reliability when the first chain failed.

Keywords: CHAIN, AMPUTATED, INADEQUATE MAINT, POWER PRESS, WORK RULES, EQUIPMENT FAILURE, PRESS OPERATOR, HAND, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300204054 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.