Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200230175 - Employee killed when run over by forklift

Accident Summary Nr: 200230175 -- Report ID: 1032500 -- Event Date: 03/20/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30020375903/21/199750510Rocky Mountain Pipe Company (Liberty Pipe Company)

Abstract: On March 20, 1997, Employee #1 was operating a Bobcat 974 skid steer industrial truck when it tipped forward. He was ejected from the cab and died after being run over by the unmanned vehicle. The truck was overloaded, and Employee #1 was not wearing his seat belt.

Keywords: EJECTED, IND TRK OPERATOR, WORK RULES, OVERLOADED, INDUSTRIAL TRUCK, SEAT BELT, MECH MAT HANDLING, UNMANNED, RUN OVER, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300203759 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close