Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200212124 - Flange Strikes Worker Who Falls from Elevation and Is Killed

Accident Summary Nr: 200212124 -- Report ID: 0626000 -- Event Date: 11/03/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
31045146311/04/20061791238120Caldwell Tanks, Inc.

Abstract: On November 3, 2006, employees were lowering a construction flange, when the flange and a piece of a swivel arm swung and struck Employee #1. He lost his balance, and slid from the top of a water tank and down the side of the tank. Employee #1 had donned a full body harness and two shock absorber lanyards. Instead of hooking his lanyards to the anchorage point located on top of the water tank, Employee #1 attached each lanyard to the side harness D-rings. Employee #1 fell approximately 129 ft to the ground and was killed.

Keywords: WATER TOWER, WORK RULES, WELDER, CONSTRUCTION, FALL, STRUCK BY, LOST BALANCE, TIE-OFF, WATER TANK, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator New project or new addition $500,000 to $1,000,000 129 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310451463 Fatality Other Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: 129 feet
Cause: Steel Erection Of Solid Web-Welding/Burning/Grindi
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close