Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200211498 - Employee is killed in clothing compactor

Accident Summary Nr: 200211498 -- Report ID: 0626000 -- Event Date: 07/27/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30789363608/02/20044226493190Texas Rag Exports Inc Dba La Bodega Maria

Abstract: On July 27, 2004, Employee #1 was operating a hydraulic-powered compactor/baler machine at a large warehouse in a foreign trade zone. The machine baled used clothing into 100-lb bales. Employee #1 climbed under the machine for unknown reasons and was crushed when the machine was switched to release. Soon thereafter, he died of internal injuries. Employee #1 had received little or no training in the machine's operation. The machine's control panel labels and warning signage were poor.

Keywords: CLOTHING, LOCKOUT, CRUSHED, HYDRAULIC TOOL, INEXPERIENCE, BALER, STORAGE AREA, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307893636 Fatality Asphyxia Compressing and compacting machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.