Accident Report Detail
Accident Summary Nr: 200203271 - 19 Employees Are Injured When Canopy Walk Collapses, One Die
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 312770092 | 12/19/2008 | 1771 | 238140 | Southern Decorative Concrete Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312770282 | 12/19/2008 | 1799 | 238990 | Pioneer Concrete Pumping Service, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312770308 | 12/19/2008 | 1791 | 238120 | Williams Erection Company |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312770092 | 12/19/2008 | 1771 | 238140 | Southern Decorative Concrete Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312770290 | 01/12/2009 | 3299 | 327999 | Forta Corporation |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 312770092 | 12/19/2008 | 1771 | 238140 | Southern Decorative Concrete Inc. |
Abstract: At approximately 9:00 a.m. on December 19, 2008, Employees were pouring concrete onto a metal decking (walking area) structure for the Atlanta Botanical Garden Canopy Walk construction project. They were working from an elevated structure approximately 400 ft long (compose of several 30 ft sections) and approximately 35 ft from the ground. After pouring approximately 25 to 30 yd of concrete, the structure suddenly collapsed, killing Employee #1 and injuring 19 others, 10 of those employees were hospitalized. Based on the onsite investigation and interviews, noncompliance with the shoring tower design caused the accident. The shoring contractor failed to comply with the design, because three of the steel beams used in shoring towers number 6 and 9 did not meet structural design requirements, and the helical anchor was inadequately embedded in the soil and not braced for shoring towers of 20 ft or greater in height requirement. Additionally, the shoring contractor did not provide the required diagonal cable bracings between the anchors. Anchors with shallow depths would make them highly susceptible to differential settlement and lateral movements. This created the collapse hazard. The shoring contractor had received instructions to provide lateral bracings. Seven anchors under tower number 7 and 8 had embedment depths that varied from 43 in. to 17 in., but none were braced.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | New project or new addition | $5,000,000 to $20,000,000 | 35 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 312770092 | Hospitalized injury | Fracture | Concrete and terrazzo finishers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 2 | 312770092 | Non Hospitalized injury | Fracture | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 3 | 312770092 | Non Hospitalized injury | Cut/Laceration | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 4 | 312770092 | Non Hospitalized injury | Cut/Laceration | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 5 | 312770092 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 6 | 312770092 | Non Hospitalized injury | Strain/Sprain | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 7 | 312770092 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 8 | 312770092 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 9 | 312770282 | Hospitalized injury | Fracture | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 10 | 312770308 | Non Hospitalized injury | Bruise/Contus/Abras | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 11 | 312770092 | Hospitalized injury | Fracture | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 12 | 312770092 | Hospitalized injury | Fracture | Concrete and terrazzo finishers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 13 | 312770092 | Hospitalized injury | Fracture | Carpenters | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 14 | 312770092 | Hospitalized injury | Fracture | Concrete and terrazzo finishers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 15 | 312770092 | Hospitalized injury | Fracture | Carpenters | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 16 | 312770092 | Hospitalized injury | Cut/Laceration | Carpenters | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 17 | 312770092 | Fatality | Fracture | Carpenters | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 18 | 312770092 | Hospitalized injury | Fracture | Concrete and terrazzo finishers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |
||
| 19 | 312770290 | Non Hospitalized injury | Fracture | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||
| 20 | 312770092 | Hospitalized injury | Fracture | Concrete and terrazzo finishers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pouring or installing floor decks Fatality Cause: Collapse of structure |