Accident Report Detail

Accident Summary Nr: 200200079 - Employee killed when crushed by forklift

Accident Summary Nr: 200200079 -- Report ID: 0418200 -- Event Date: 05/16/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
10929440505/17/199624210Babb Lumber Company, Inc.

Abstract: Employee #1, a truck driver, was helping to load an empty flatbed trailer with lumber for delivery to a customer. Two stacks of lumber had been loaded onto the back of the trailer just prior to the accident. The forklift operator picked up a third stack to be loaded on top of the back right stack. He approached the trailer from the right side with the load up, stopped on a slight incline about a foot from the trailer, set the parking brake, left the motor running, and got off to align some dunnage on the stack that was already on the trailer. At the same time, Employee #1 decided to help move the dunnage and he stepped between the load and the trailer. When he was approximately in the center of the load, the parking brake on the forklift let go and the forklift began to roll. Employee #1 was crushed between the load and the trailer. He was killed.

Keywords: LOADING, VEHICLE IN GEAR, BRAKE, EQUIPMENT FAILURE, CRUSHED, INDUSTRIAL TRUCK, MECH MAT HANDLING, UNMANNED, SLOPE, TRUCK DRIVER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109294405 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close