Accident Summary Nr: 200150209 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU TV CABLE

Accident Summary Nr: 200150209 -- Report ID: 0214700 -- Event Date: 09/08/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30013939109/09/199848410Cablevision

Abstract: A cable television line worker was removing a length of service drop cable that had been damaged in a storm. The damaged cable was draped over the cable strand running between two utility poles. The employee, who was not wearing rubber insulating gloves, was standing on the ground, removing the cable from the cable strand. The end of the cable apparently whipped upward into a 7600-volt overhead power line, electrocuting the employee. (Electrical burns were found on his left hand and right foot.)

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CABLE TV WORK, COMMUNICATION CABLE, E TC, ELECTROCUTED, COMMUNICATION WORKER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300139391 Fatality Electric Shock Telephone line installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.