Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200122380 - One killed, one injured when drill rig contacts power line

Accident Summary Nr: 200122380 -- Report ID: 0523400 -- Event Date: 03/20/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30527738603/21/20031781237110Hoover Well Drilling Company, Inc.

Abstract: On March 20, 2003, Employees #1 and #2 were operating a drill rig to drill a well. In the course of their work, the rig contacted an overhead power line. Employee #1, the drill operator, was electrocuted. Employee #2 received an electric shock and sustained injuries that required hospitalization.

Keywords: CLEARANCE, OVERHEAD POWER LINE, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, DRILL RIG--NON-OIL, ELECTRIC SHOCK
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $50,000 to $250,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 305277386 Fatality Electric Shock Miscellaneous machine operators, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electrocution by equipment contacting wire
2 305277386 Hospitalized injury Electric Shock Miscellaneous machine operators, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electric shock, other and unknown cause

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.