Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200120012 - Employee dies of injuries in fall through roof opening

Accident Summary Nr: 200120012 -- Report ID: 0523400 -- Event Date: 06/19/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
30011060806/20/199617610J.T. Roofing, Inc.

Abstract: Employee #1 was one of two foreman of a crew of seven that was engaged in placing a large flat roof on a new drugstore under construction in a shopping plaza. Their job involved positioning two layers of insulation on a steel corrugated deck and covering them with sheet rolls of rubber membranes, solvent-welded together, that would be held in place by a layer of round rocks. At approximately 10:30 a.m., the other foreman asked the general contractor's job superintendent to cut a 36 in. by 30 in. roof hatch opening in the metal decking at the northeast area of the roof. The job superintendent placed a 48 in. by 45 in. by 5/8 in. thick piece of plywood over the opening, but did not secure it because the roofing subcontractor was going to install curbing around its perimeter. Employee #1 was last seen using a key hole saw and utility knife to cut and position insulation around the unguarded opening. He apparently fell approximately 19 ft 2 in. through the roof opening. At approximately 4:20 p.m., Employee #1 was found on the concrete floor at ground level, bleeding profusely from the head. He was transported to the hospital, where he later died. There were no witnesses to this accident. The employer had a generic fall protection program not specific to the site, and which did not address other forms of fall protection for employees performing jobs involving roof openings. This accident might have been avoided if the opening been guarded, as required by 29 CFR 1926.501(b)(4), or if the employee had been provided fall protection measures such as a scaffold or a safety net.

Keywords: ROOF OPENING COVER, HEAD, UNSECURED, WORK RULES, CONSTRUCTION, FALL, FALL PROTECTION, ROOF OPENING, UNGUARDED, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $500,000 to $1,000,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300110608 Fatality Fracture Roofers Distance of Fall: feet
Worker Height Above Ground/Floor: 19 feet
Cause: Roofing
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close