Accident: 200102531 - Employee Is Asphyxiated After Being Pinned By Forklift

Accident: 200102531 -- Report ID: 0522300 -- Event Date: 10/04/2006
InspectionOpen DateSICEstablishment Name
31032904010/04/20063991Wooster Brush Company Plant #2

At about 9:45 a.m. on October 4, 2006, Employee #1 was reversing a Raymond Reach Fork Truck when she was pinned between the truck and a cross beam of a shelving unit located behind her. The cross beam caught the employee above the waist, causing her to bend forward and pin her onto the truck. There were no signs or warning labels found on the operator station to inform the operator of a backup hazard. The forklift was designed so the operator stands up to operate the equipment and there was no barrier or cab designed in the upper portion of the vehicle to protect the operator. Employee #1 had been employed by the employer for about 8 years prior to the incident, but had been working with this model forklift for about two months and had received 40 hours of training on the equipment. At the time of the incident there were no other employees in the vicinity. Employee #1 was found unconscious, and a supervisor dislodged her by having another forklift raise the cross beam. The supervisor also performed CPR until an emergency medical services unit arrived. Employee #1 died of asphyxiation as a result of the incident.

Keywords: beam, asphyxiated, vehicle in gear, pinned, driver, caught between, industrial truck, backing up, warning sign

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 310329040 Fatality Asphyxia Freight, stock and material handlers, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.