Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200090579 - Employee Is Killed When Struck by Steel Plate

Accident Summary Nr: 200090579 -- Report ID: 0112300 -- Event Date: 08/04/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30757820308/04/20063441332312Capco Steel

Abstract: On August 4, 2006, Employee #1 was standing nearby, while a coworker lifted a 4,900 lb steel plate with an overhead crane, at Capco Steel. Attached to the crane was a plate clamp lifting device that was rated for 4,000 lbs. When the plate was lifted, it slipped out of the clamp lifting device and fell. The plate struck him on the head, killing him. The employees had not been adequately trained in the safe use of the crane.

Keywords: STEEL PLATE, HEAD, OVERLOADED, OVERHEAD CRANE, STRUCK BY, FALLING OBJECT, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307578203 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close