Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200090231 - Employee killed when tractor cab crushed

Accident Summary Nr: 200090231 -- Report ID: 0112300 -- Event Date: 06/28/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30266891806/29/200042120Cuppernell Brothers Co.

Abstract: Employee #1 and a coworker were both transporting low permeable material from the Big Dig highway and bridge development project in Boston, MA to the Rhode Island Resource and Recovery landfill in Johnston, RI. The end-dump trailer trucks were parked side by side, 3 ft away from one another, while dumping the material at the landfill. The load in one of the end dump trailers shifted to the side while the trailer was raised, causing the trailer to fall over onto the tractor of the adjacent truck. The cab was crushed, killing Employee #1. The cause of the accident was side by side dumping.

Keywords: CLEARANCE, WORK RULES, LOAD SHIFT, CRUSHED, DUMP TRUCK, TRACTOR--TRUCK, DUMP TRUCK BED, OVERTURN, TRUCK DRIVER, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302668918 Fatality Asphyxia Truck drivers, heavy

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close