Accident Summary Nr: 200083343 - Employee Is Killed When Run over by Fuel Truck

Accident Summary Nr: 200083343 -- Report ID: 0112000 -- Event Date: 01/28/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31175476601/28/20085983454311Klingner Family Oil

Abstract: On January 28, 2008, Employee #1, the owner of a home heating oil delivery service, was training a new employee. The employee was driving a fuel truck, and Employee #1 was in the passenger seat as they arrived at a single-family home to deliver heating oil. They backed the truck into the home's driveway, which had a 12-degree slope. The vehicle's parking brake was inoperable, so Employee #1 moved to the driver's side and held the foot brake with his hand while the new employee pumped oil. When Employee #1 slipped and fell, the truck rolled over him and killed him.

Keywords: BRAKE, INADEQUATE MAINT, WORK RULES, SLIP, EQUIPMENT FAILURE, TRUCK, FALL, RUN OVER, SLOPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311754766 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close