Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200080950 - Employee killed in fall through gypsum roof decking

Accident Summary Nr: 200080950 -- Report ID: 0112000 -- Event Date: 10/24/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12333671110/24/200017610Premier-New York, Inc.

Abstract: Employee #1 was removing the exterior surface of the roof of a school building. He was taking off a piece of flashing at the east wall of the roof when the gypsum roof decking collapsed under him. He fell to the ground and was killed. The roof at that spot had apparently been wet for a sustained period in the past, causing the gypsum to lose its structural integrity. The wire mesh that reinforced the gypsum had rusted away in some places and had shrunk in coverage in other locations. Prior to the start of the job, the structural integrity of the roof deck was reportedly evaluated for the purpose of supporting workers and their equipment.

Keywords: ROOF, ROOF DECKING, WORK RULES, CONSTRUCTION, UNSTABLE SURFACE, FALL, ROOF PANEL, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Demolition $5,000,000 to $20,000,000 2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 123336711 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Collapse of structure

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close