Accident Summary Nr: 200080307 - Employee's arm injured when caught by garbage truck ram

Accident Summary Nr: 200080307 -- Report ID: 0112000 -- Event Date: 12/17/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
11614075712/20/199949530F.E. Crandall Disposal Company, Inc.

Abstract: Employee #1 was working on a side-loading garbage truck when the compacting arm became stuck in the open position. He tried to free the ram and was reaching through the zone of operation to trip the microswitch control when the ram suddenly descended and caught Employee #1's left arm. He was treated at the hospital, but his arm had to be surgically amputated due to extensive and irreparable damage and subsequent necrosis.

Keywords: HYDRAULIC RAM, GARBAGE TRUCK, AMPUTATED, STUCK, WORK RULES, CAUGHT BETWEEN, CRUSHED, ARM, RAM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116140757 Hospitalized injury Amputation Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.