Accident Report Detail
Accident Summary Nr: 200071819 - Two Killed, When Concrete Wall Panel Overturns
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 305746331 | 08/05/2002 | 1542 | 236220 | Perry Construction Group, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305746349 | 08/05/2002 | 1791 | 0 | Carolina Tiltup Construction, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305746364 | 08/07/2002 | 1791 | 0 | Steel Performance, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305746315 | 08/05/2002 | 1711 | 0 | Associated Sprinkler Company Llc |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305748204 | 09/18/2002 | 1791 | 0 | Carolina Steel & Stone, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305747040 | 08/22/2002 | 5251 | 444130 | Home Depot U.S.A. Inc. -Store 3651 |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 305746372 | 08/12/2002 | 8711 | 541330 | Professional Service Industries, Inc. |
Abstract: On August 5, 2002, Employee #1 and #2, of Associated Sprinkler Company and three coworkers, of Lowder, Inc., were waiting their lunches near a recently-installed 20ft wide by 23ft tall, 40,000lb reinforced concrete tilt-up wall panel. The wall suddenly fell on the workers, killing Employee #1 and #2 and one of the coworkers, and injuring the other two coworkers. The temporary braces for the wall panel had been removed approximately two hours earlier by the contractor and before permanent connections at the roof and base had been made. According to the job specifications, the wall panel was to have been welded to the roof, grouted to the footing, and tied into the floor slab by a pour-back strip before the braces were removed. None of these connections had been made, as a result once the braces were removed; the wall panel was free standing , on a set of shims. In additions, an independent testing company was supposed to inspect all welds and issue a report. The report was incorrect in indicating that all the welds were complete when, in fact, two wall panels were not welded at all, one of them being the panel that fell.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Commercial building | New project or new addition | $5,000,000 to $20,000,000 | 1 | 23 | X | ||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 305746331 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||||
| 2 | 305746349 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||||
| 3 | 305746364 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||||
| 4 | 305746315 | Fatality | Other | Mechanical engineers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Exterior masonry Fatality Cause: Collapse of structure |
||
| 5 | 305746315 | Fatality | Other | Plumber, pipefitter and steamfiter apprentices | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Exterior masonry Fatality Cause: Collapse of structure |
||
| 6 | 305748204 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||||
| 7 | 305747040 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||||
| 8 | 305746372 | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |