Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200070894 - Three employees killed in fall from communications tower

Accident Summary Nr: 200070894 -- Report ID: 0453720 -- Event Date: 12/03/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30293063112/09/199917210Daniel Zortman Dba The Quality Tower Painting Comp

Abstract: Employee #1, the company owner, Employee #2, age 19, and Employee #3, age 16, were ascending a 1,500 ft tall communications tower. They were using a practice referred to in the industry as riding the line. They were all tied to loops in a 3/4 in. nylon rope, one above the other, with Employee #3 on top, Employee #2 in the middle, and Employee #1 on the bottom. Each man was carrying assorted equipment, such as paint and tools, and an approximately 100 lb rest platform was attached to the bottom of the rope. The men and their equipment were being raised to work areas on the tower by a coworker using a capstan hoist with a 1,000 lb lift capacity. They were going up the outside of the 7 ft by 7 ft by 7 ft guyed tower when the rope on the drum of the capstan hoist became loose. The coworker was unable to control the rope and the three employees and their equipment fell approximately 1,000 ft to the ground. Employees #1 through #3 were killed.

Keywords: MAINTENANCE, COMMUNICATION TOWER, HOISTING MECHANISM, UNSECURED, WORK RULES, CONSTRUCTION, HOIST, FALL, TOWER, HOISTLINE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Alteration or rehabilitation Under $50,000 1500 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302930631 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 1000 feet
Cause: Exterior painting
Fatality Cause: Fall, other
2 302930631 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 1000 feet
Cause: Exterior painting
Fatality Cause: Fall, other
3 302930631 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 1000 feet
Cause: Exterior painting
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.