Accident Summary Nr: 200070662 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

Accident Summary Nr: 200070662 -- Report ID: 0453720 -- Event Date: 05/19/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30247167705/24/199916230C & V Utilities, Inc.

Abstract: A contractor was installing an underground water line during the construction of a finished water plant. Because of the force created by the pumps in the plant, the contractor was constructing thrust blocks for two joints in the water line. The contractor's employees were using a 27.2-metric-ton Trandano truck crane (Model No. TR-300XL) to move ready-mix concrete in a 0.39-cubic-meter GAR-BRO concrete bucket from a concrete truck to the forms for the blocks. The crane and truck were located on one side of a 44-kilovolt (25.4-kilovolt, phase-to-ground) overhead power line, which crossed the construction site. The employees positioned the truck and the crane on the same side of the power line to avoid operating the crane close to the line. After the employees finished off-loading the concrete, the truck driver moved his truck to an area on the other side of the power line, so that he could wash out the chute. The truck operator offered to wash out the concrete bucket if the crane operator moved the bucket to the wash area. The crane operator accepted the offer and started moving the bucket. A signaler directed the movement of the bucket. The load line on the crane contacted the power line. The signaler was walking next to the concrete bucket and was apparently touching the bucket. He received an electric shock and sustained severe burns to his left hand, left leg, and right foot. An emergency medical services team transported the injured employee to the local hospital, and a medevac subsequently transported him to a burn center, where he was hospitalized. Doctors amputated the employee's left hand and arm 100 millimeters below his elbow; his left foot 200 millimeters below his left knee; and a portion of the right foot and toes.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, CONSTRUCTION, E C, ELECTRIC SHOCK, LOAD LINE, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant New project or new addition $500,000 to $1,000,000 1

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302471677 Hospitalized injury Amputation Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.