Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200053601 - Employee Is Burned by Hot Asphalt During Transfer Operation

Accident Summary Nr: 200053601 -- Report ID: 0728900 -- Event Date: 07/13/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31146748407/13/20092951324121Monarch Oil, Inc.

Abstract: At approximately 8:45 a.m. on July 13, 2009, Employee #1 was one of three employees unloading asphalt product from rail cars and into storage tanks. During the transfer process, the system experienced an increase in pressure. The hose in use, a hot asphalt transfer hose, separated from its fitting. When the hose separated, heated asphalt product was released from the system via the open valve on the rail header. Employee #1 was positioned under the railcar when the asphalt covered him. The asphalt was approximately 240-degrees Fahrenheit at the time of the exposure. Employee #1 suffered severe burns and was hospitalized.

Keywords: BURN, RAILROAD CAR, HOSE, HOT ASPHALT, VALVE, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311467484 Hospitalized injury Burn/Scald(Heat) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close