Accident Summary Nr: 200053478 - Man Basket Falls Over; Worker Dies Later

Accident Summary Nr: 200053478 -- Report ID: 0728900 -- Event Date: 05/12/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31146681705/12/20091799238990Diamond Sawing & Coring, L.L.C.

Abstract: Two workers were working at an Air National Guard facility for a construction contractor that sawed concrete. They were tied off in a man basket attached to a forklift mast, which was in turn connected to a Caterpillar skid steer loader. As they started to cut into the side of the building with a diamond tip saw, the man basket started to fall backward over the top of the skid steer loader. The workers were tied into the basket and were forced to ride the basket down. They were thrown onto a concrete flight line below. Both workers were taken to the hospital for their injuries. One worker died days later, but the disposition of the other was not mentioned in this report.

Keywords: CONSTRUCTION, SAW, INDUSTRIAL TRUCK, FALL, LOADER, CONCUSSION, ELEVATED WORK PLAT, FALLING OBJECT, CONCRETE, EQUIPMENT APPROVAL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building Alteration or rehabilitation $500,000 to $1,000,000 2 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311466817 Fatality Concussion Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 25 feet
Cause: Cutting concrete pavement
Fatality Cause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.