Accident Summary Nr: 200053064 - Employee killed in fall from steel-framed structure

Accident Summary Nr: 200053064 -- Report ID: 0728900 -- Event Date: 08/25/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30868621108/27/20071791238120Moen Steel Erection

Abstract: On August 25, 2007, Employee #1, a journeyman steel erector, and a coworker were installing metal decking on a steel-framed structure. They first discussed the job while in a safe area on the roof, where the decking had been installed and finished and which was marked with warning lines. Employee #1 and the coworker were wearing harnesses equipped with a double-lanyard system connected to a D-ring between the shoulder blades. When they finished talking, the coworker turned to walk away from the area to connect to a retractable system so that he could move out onto a girder and install a horizontal lifeline system. The coworker heard a yell, turned back around, and saw Employee #1 falling. He dropped 26 ft to the ground and died of head injuries sustained in the fall. Employee #1 was found with one of the double lanyards attached to the side D-ring on the harness and the second hanging freely. The site had a 100 percent tie-off policy for any employee or subcontractor working higher than 6 ft. For this reason, the site did not allow the use of controlled decking zones, as outlined in Subpart R of 29 CFR 1926.

Keywords: ERECTION PROCESS, HEAD, IRON WORKER, WORK RULES, CONSTRUCTION, STEEL ERECTION, FALL, FALL PROTECTION, WALKING ON BEAM, TIE-OFF
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $1,000,000 to $5,000,000 26 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 308686211 Fatality Concussion Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 26 feet
Cause: Erecting structural steel
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.